One Peachtree Center: Atlanta Georgia
Presented in this paper are the architectural and structural concepts of One Peachtree Center built in the city of Atlanta. This 62-story tall building has changed the downtown skyline...

One Ninety One Peachtree and NationsBank: Composite Additions to the Atlanta Skyline
The structural design of two composite buildings in Atlanta is described in this paper. A composite exterior partial tube was used in one case and a composite super-column system was utilized...

Steel Compression Member Design in the 1994 Canadian Standard
The 1994 edition of CSA Standard S 16.1-M94, Limit states design of steel structures (CSA 1994) contains explicit methods for computing the compressive resistance of monosymmetric and...

Impulsive Punching of Fiber-Reinforced Concrete Slabs
The behavior of FRC slabs reinforced with polymeric fibers (polyacrylonitrile fibers PAN) and subjected to impulsive punching is analyzed here in order to clarify to what extent the fibers...

Moment-Rotation Behavior of Pultruded Beam-to-Column Connections
Presented are experimental details and results of five tests carried out to study the moment-rotation behavior of flange cleated connections for frames of pultruded members. The full-sized...

Progress in Reinforced Concrete Column Design: An Introduction
The Joint ASCE-ACI Committee 441 on Reinforced Concrete Columns is investigating a number of problems related to structural behavior and design of reinforced concrete columns. This paper...

Design of Lateral Steel in Columns
Lateral steel in columns is generally required for shear resistance, confinement of concrete and prevention of buckling of longitudinal bars. This paper is limited to the design of lateral...

Rational Limits for Longitudinal Steel in Concrete Columns
Current limits for the amount of longitudinal reinforcement in concrete columns were established more than 60 years ago. Commercial grades of reinforcement in 1930 were about half as strong...

High-Strength Concrete Columns: State of the Knowledge
This paper consists of reported information divided into two general categories, performance of High-Strength Concrete (HSC) columns under concentric loads, and combined axial and bending...

Progress in Reinforced Concrete Column Design
This paper reviews some of the design procedures used for both braced and unbraced frames constructed in reinforced concrete. The discussion refers to the problems of material and geometric...

Creep Analysis of Composite Steel-Concrete Members with Deformable Connectors
The long-term analysis of composite steel-concrete beams with elastically deformable connectors is presented. The basic integro-differential equation governing the problem is solved by...

Steel-Concrete Interaction by Means of Film Sensors
By adapting a recently-developed technique based on the piezoelectrical properties of relatively thick films made of Polyvinyldifluor organic composites and extensively used in robotics,...

Shear Design Guidelines for Polyester Concrete Using Recycled Plastic
Previous research on the shear behavior of steel-reinforced polymer concrete (PC) beams has been very limited and no efficient design procedures have been proposed. In all the previous...

Load Carrying Capacity of SPC Composite Column
This paper reports the result of beam column test of a new type composite columns. High-strength precast-concrete panels (hereafter denoted as PCa-panels) are fixed to the steel square...

Dynamic Response of Steel Fiber Reinforced Concrete
Extensive research has been done on the static properties of steel fiber reinforced concrete, but very little on the dynamic properties. A total of 20 beams was tested. The steel fiber...

Special Considerations in the Design of Connections for Recycled Wood/Plastic Composite Lumber
There is current work in the American Society for Testing and Materials (ASTM) to evaluate potential test methods for what they refer to as 'commingled' plastic lumber. This category covers...

Cyclical Behavior of Welded Steel Shear Studs
Four specimens of composite steel and concrete beams were experimentally tested to obtain the cyclical behavior of the welded steel shear stud. This information may be used for the analysis...

Cyclic Behavior of Joints Between Steel Beams and Reinforced Concrete Columns
The design and behavior of composite beam-column joints for seismic design are reviewed based on the results of tests. Issues addressed include the strength, deformation, and toughness...

Recent Studies of the Behaviour of Semi-Rigid Composite Connections
Following renewed interest in the semi-rigid properties of joints in steel frame structures, a more recently identified area of research has been the study of composite connections. The...

Rigid Beam-To-Column Connection Detail for Circular Composite Columns
Steel pipes with relatively thin wall thickness and filled with high strength concrete have been used in building construction. Some of the advantages of this type of column include eliminating...

 

 

 

 

Return to search